Files
2024-05-18 23:53:26 +08:00

297 lines
16 KiB
C

/**
* @file GoHealth.h
* @brief Declares the GoHealthMsg class and related types.
*
* @internal
* Copyright (C) 2016-2021 by LMI Technologies Inc.
* Licensed under the MIT License.
* Redistributed files must retain the above copyright notice.
*/
#ifndef GO_SDK_HEALTH_H
#define GO_SDK_HEALTH_H
#include <GoSdk/GoSdkDef.h>
#include <kApi/Io/kSerializer.h>
/**
* @struct GoHealthIndicatorId
* @ingroup GoSdk-HealthChannel
* @brief Represents a health indicator ID.
*
* The following enumerators are defined:
* - #GO_HEALTH_ENCODER_VALUE
* - #GO_HEALTH_ENCODER_FREQUENCY
* - #GO_HEALTH_LASER_SAFETY
* - #GO_HEALTH_FIRMWARE_VERSION
* - #GO_HEALTH_FIRESYNC_VERSION
* - #GO_HEALTH_UPTIME
* - #GO_HEALTH_TEMPERATURE
* - #GO_HEALTH_TEMPERATURE_EXTENDED
* - #GO_HEALTH_PROJECTOR_TEMPERATURE
* - #GO_HEALTH_LASER_TEMPERATURE
* - #GO_HEALTH_LASER_OVERHEAT
* - #GO_HEALTH_LASER_OVERHEAT_DURATION
* - #GO_HEALTH_OVERHEAT
* - #GO_HEALTH_OVERHEAT_DURATION
* - #GO_HEALTH_CPU_TEMPERATURE
* - #GO_HEALTH_CAMERA_0_TEMPERATURE
* - #GO_HEALTH_CAMERA_1_TEMPERATURE
* - #GO_HEALTH_LASER_DRIVER_TEMPERATURE
* - #GO_HEALTH_MEMORY_USED
* - #GO_HEALTH_MEMORY_CAPACITY
* - #GO_HEALTH_STORAGE_USED
* - #GO_HEALTH_STORAGE_CAPACITY
* - #GO_HEALTH_CPU_USED
* - #GO_HEALTH_SYNC_SOURCE
* - #GO_HEALTH_NET_OUT_USED
* - #GO_HEALTH_NET_OUT_RATE
* - #GO_HEALTH_NET_OUT_CAPACITY
* - #GO_HEALTH_NET_OUT_LINK_STATUS
* - #GO_HEALTH_DIGITAL_INPUTS
* - #GO_HEALTH_EVENT_COUNTS
* - #GO_HEALTH_CAMERA_SEARCH_COUNT
* - #GO_HEALTH_CAMERA_TRIGGER_DROPS
* - #GO_HEALTH_CUDA_STATUS
* - #GO_HEALTH_STATE
* - #GO_HEALTH_SPEED
* - #GO_HEALTH_MAXSPEED
* - #GO_HEALTH_SPOT_COUNT
* - #GO_HEALTH_MAX_SPOT_COUNT
* - #GO_HEALTH_SCAN_COUNT
* - #GO_HEALTH_VALID_POINT_COUNT
* - #GO_HEALTH_MAX_POINT_COUNT
* - #GO_HEALTH_MASTER_STATUS
* - #GO_HEALTH_CAST_START_STATE
* - #GO_HEALTH_ALIGNMENT_STATE
* - #GO_HEALTH_PLAYBACK_POSITION
* - #GO_HEALTH_PLAYBACK_COUNT
* - #GO_HEALTH_DIGITAL_OUTPUT_HIGH_COUNT
* - #GO_HEALTH_DIGITAL_OUTPUT_LOW_COUNT
* - #GO_HEALTH_PROCESSING_LATENCY_LAST
* - #GO_HEALTH_PROCESSING_LATENCY_MAX
* - #GO_HEALTH_PROCESSING_DROPS
* - #GO_HEALTH_TRIGGER_DROPS
* - #GO_HEALTH_OUTPUT_DROPS
* - #GO_HEALTH_ANALOG_DROPS
* - #GO_HEALTH_DIGITAL_DROPS
* - #GO_HEALTH_SERIAL_DROPS
* - #GO_HEALTH_CONTROLLED_TRIGGER_DROPS
* - #GO_HEALTH_SURFACE_PROCESSING_TIME
* - #GO_HEALTH_MAX_FRAME_RATE
* - #GO_HEALTH_ETHERNET_DROPS
* - #GO_HEALTH_RANGE_VALID_COUNT
* - #GO_HEALTH_RANGE_INVALID_COUNT
* - #GO_HEALTH_ANCHOR_INVALID_COUNT
* - #GO_HEALTH_LIGHT_OPERATIONAL_TIME_TOTAL
* - #GO_HEALTH_FIRST_LOG_ID
* - #GO_HEALTH_LAST_LOG_ID
* - #GO_HEALTH_ENCODER_Z_INDEX_PULSE_DROPS
* - #GO_HEALTH_TOOL_RUN_TIME
* - #GO_HEALTH_PART_TOTAL_EMITTED
* - #GO_HEALTH_PART_LENGTH_LIMIT
* - #GO_HEALTH_PART_MIN_AREA_DROPS
* - #GO_HEALTH_PART_BACKTRACK_DROPS
* - #GO_HEALTH_PART_CURRENTLY_ACTIVE
* - #GO_HEALTH_PART_LENGTH
* - #GO_HEALTH_PART_START_Y
* - #GO_HEALTH_PART_TRACKING_STATE
* - #GO_HEALTH_PART_CAPACITY_EXCEEDED
* - #GO_HEALTH_PART_X_POSITION
* - #GO_HEALTH_TOOL_RUN_TIME_MIN
* - #GO_HEALTH_TOOL_RUN_TIME_MAX
* - #GO_HEALTH_TOOL_RUN_TIME_AVERAGE
* - #GO_HEALTH_TOOL_RUN_TIME_PERCENT
* - #GO_HEALTH_MEASUREMENT
* - #GO_HEALTH_MEASUREMENT_PASS
* - #GO_HEALTH_MEASUREMENT_FAIL
* - #GO_HEALTH_MEASUREMENT_MIN
* - #GO_HEALTH_MEASUREMENT_MAX
* - #GO_HEALTH_MEASUREMENT_AVERAGE
* - #GO_HEALTH_MEASUREMENT_STDEV
* - #GO_HEALTH_MEASUREMENT_INVALID_COUNT
* - #GO_HEALTH_MEASUREMENT_OVERFLOW_COUNT
*/
typedef k32s GoHealthIndicatorId;
/** @name GoHealthIndicatorId
*@{*/
#define GO_HEALTH_ENCODER_VALUE (1003) ///< Current system encoder tick.
#define GO_HEALTH_ENCODER_FREQUENCY (1005) ///< Current system encoder frequency (ticks/s).
#define GO_HEALTH_LASER_SAFETY (1010) ///< Laser safety status.
#define GO_HEALTH_FIRMWARE_VERSION (2000) ///< Firmware application version.
#define GO_HEALTH_FIRESYNC_VERSION (20600) ///< FireSync version
#define GO_HEALTH_UPTIME (2017) ///< Time elapsed since boot-up or reset (seconds).
#define GO_HEALTH_TEMPERATURE (2002) ///< Internal temperature (degrees Celsius).
#define GO_HEALTH_TEMPERATURE_EXTENDED (20009) ///< Internal temperature extended (supports multiple devices, degrees Celsius).
#define GO_HEALTH_PROJECTOR_TEMPERATURE (2404) ///< Projector temperature (degrees Celsius).
#define GO_HEALTH_LASER_TEMPERATURE (2028) ///< Laser temperature (degrees Celsius). Available only on 3B-class devices.
#define GO_HEALTH_LASER_OVERHEAT (20020) ///< Indicates whether the laser is overheating. (DEPRECATED)
#define GO_HEALTH_LASER_OVERHEAT_DURATION (20021) ///< Indicates how long the laser has been overheating if it is overheating. (DEPRECATED)
#define GO_HEALTH_OVERHEAT (20020) ///< Indicates whether the sensor is overheating.
#define GO_HEALTH_OVERHEAT_DURATION (20021) ///< Indicates how long the sensor has been overheating if it is overheating.
#define GO_HEALTH_CPU_TEMPERATURE (20011) ///< CPU temperature (degrees Celsius).
#define GO_HEALTH_CAMERA_0_TEMPERATURE (20012) ///< Camera 0 temperature (degrees Celsius).
#define GO_HEALTH_CAMERA_1_TEMPERATURE (20013) ///< Camera 1 temperature (degrees Celsius).
#define GO_HEALTH_LASER_DRIVER_TEMPERATURE (20014) ///< Laser driver temperature (degrees Celsius).
#define GO_HEALTH_MEMORY_USED (2003) ///< Amount of memory currently used (bytes).
#define GO_HEALTH_MEMORY_CAPACITY (2004) ///< Total amount of memory available (bytes).
#define GO_HEALTH_STORAGE_USED (2005) ///< Amount of non-volatile storage used (bytes).
#define GO_HEALTH_STORAGE_CAPACITY (2006) ///< Total amount of non-volatile storage available (bytes).
#define GO_HEALTH_CPU_USED (2007) ///< CPU usage (percentage of maximum).
#define GO_HEALTH_SYNC_SOURCE (2043) ///< Sensor synchronization source. (1 - Master, 2 - Device/Gocator)
#define GO_HEALTH_NET_OUT_USED (21003) ///< Current outbound network count (bytes).
#define GO_HEALTH_NET_OUT_RATE (21004) ///< Current outbound network throughput (bytes/second).
#define GO_HEALTH_NET_OUT_CAPACITY (2009) ///< Total available outbound network throughput (bytes/s).
#define GO_HEALTH_NET_OUT_LINK_STATUS (2034) ///< The ethernet output's current network link status
#define GO_HEALTH_DIGITAL_INPUTS (2024) ///< Current digital input status (one bit per input).
#define GO_HEALTH_EVENT_COUNTS (2102) ///< Total number of events triggered.
#define GO_HEALTH_CAMERA_SEARCH_COUNT (2217) ///< Number of search states.
#define GO_HEALTH_CAMERA_TRIGGER_DROPS (2201) ///< Number of dropped triggers.
#define GO_HEALTH_CUDA_STATUS (3007) ///< Status of CUDA/GPU support on the sensor (accelerated and non-accelerated) platform.
#define GO_HEALTH_STATE (20000) ///< Current system state.
#define GO_HEALTH_SPEED (20001) ///< Current speed (Hz).
#define GO_HEALTH_MAXSPEED (20002) ///< Maximum speed (Hz).
#define GO_HEALTH_SPOT_COUNT (20003) ///< Number of found spots in the last raw/unresampled profile/surface
#define GO_HEALTH_MAX_SPOT_COUNT (20004) ///< Maximum number of spots that can be found
#define GO_HEALTH_SCAN_COUNT (20005) ///< The number of scanned profiles or surfaces.
#define GO_HEALTH_VALID_POINT_COUNT (20015) ///< The number of found points in the last resampled profile/surface
#define GO_HEALTH_MAX_POINT_COUNT (20016) ///< Maximum number of points that can be found
#define GO_HEALTH_MASTER_STATUS (20006) ///< Master connection status: 0=not connected, 1=connected
#define GO_HEALTH_CAST_START_STATE (20007) ///< The state of the second digital input.
#define GO_HEALTH_ALIGNMENT_STATE (20008) ///< The state of the sensor alignment.
#define GO_HEALTH_PLAYBACK_POSITION (20023) ///< Indicates the current replay playback index.
#define GO_HEALTH_PLAYBACK_COUNT (20024) ///< Indicates the number of frames present in the current replay.
#define GO_HEALTH_DIGITAL_OUTPUT_HIGH_COUNT (21006) ///< The number scans with high digital output pulses.
#define GO_HEALTH_DIGITAL_OUTPUT_LOW_COUNT (21007) ///< The number scans with no digital output pulse.
#define GO_HEALTH_PROCESSING_LATENCY_LAST (21001) ///< Last reported processing latency value (in uS).
#define GO_HEALTH_PROCESSING_LATENCY_MAX (21002) ///< Maximum reported processing latency.
#define GO_HEALTH_PROCESSING_DROPS (21000) ///< Current number of processing drops.
#define GO_HEALTH_TRIGGER_DROPS (21010) ///< Current number of trigger drops.
#define GO_HEALTH_OUTPUT_DROPS (21011) ///< Current number of output drops. Sum of all output drops.
#define GO_HEALTH_ANALOG_DROPS (21014) ///< Current number of analog output drops. Replaces GO_HEALTH_ANALOG_DROPS.
#define GO_HEALTH_DIGITAL_DROPS (21015) ///< Current number of digital output drops. Replaces GO_HEALTH_DIGITAL_DROPS.
#define GO_HEALTH_SERIAL_DROPS (21016) ///< Current number of serial output drops. Replaces GO_HEALTH_SERIAL_DROPS.
#define GO_HEALTH_CONTROLLED_TRIGGER_DROPS (21017) ///< Trigger drops from the Controlled Triggering System.
#define GO_HEALTH_SURFACE_PROCESSING_TIME (21018) ///< Processing time of frame on 35XX/32XX (microseconds).
#define GO_HEALTH_MAX_FRAME_RATE (21019) ///< Max configurable frame rate (scaled by 0.000001).
#define GO_HEALTH_ETHERNET_DROPS (21005) ///< Current number of ethernet output drops.
#define GO_HEALTH_RANGE_VALID_COUNT (21100) ///< Current number of frames with valid range data.
#define GO_HEALTH_RANGE_INVALID_COUNT (21101) ///< Current number of frames with invalid range data.
#define GO_HEALTH_ANCHOR_INVALID_COUNT (21200) ///< Number of frames with anchor invalid.
#define GO_HEALTH_LIGHT_OPERATIONAL_TIME_TOTAL (21201) ///< For G2 laser on time or G3 projector on time.
#define GO_HEALTH_FIRST_LOG_ID (21301) ///< ID of first available log entry
#define GO_HEALTH_LAST_LOG_ID (21300) ///< ID of last available log entry
#define GO_HEALTH_ENCODER_Z_INDEX_PULSE_DROPS (22000) ///< Encoder z-index pulse drops
#define GO_HEALTH_TOOL_RUN_TIME (22004) ///< Most recent time taken to execute the tool
#define GO_HEALTH_PART_TOTAL_EMITTED (22006) ///< Total number of parts emitted
#define GO_HEALTH_PART_LENGTH_LIMIT (22007) ///< Number of parts emitted based on length limit
#define GO_HEALTH_PART_MIN_AREA_DROPS (22008) ///< Number of parts dropped
#define GO_HEALTH_PART_BACKTRACK_DROPS (22009) ///< Number of parts dropped due to backtracking
#define GO_HEALTH_PART_CURRENTLY_ACTIVE (22010) ///< Number of parts currently being tracked
#define GO_HEALTH_PART_LENGTH (22011) ///< Length of largest active part
#define GO_HEALTH_PART_START_Y (22012) ///< Start Y position of largest active part
#define GO_HEALTH_PART_TRACKING_STATE (22013) ///< Tracking state of largest active part
#define GO_HEALTH_PART_CAPACITY_EXCEEDED (22014) ///< Part detection capacity exceeded
#define GO_HEALTH_PART_X_POSITION (22015) ///< Center X position of largets active part
#define GO_HEALTH_TOOL_RUN_TIME_MIN (22016) ///< Minimum time for tool to process a sample
#define GO_HEALTH_TOOL_RUN_TIME_MAX (22017) ///< Maximum time for tool to process a sample
#define GO_HEALTH_TOOL_RUN_TIME_AVERAGE (22018) ///< Average time for tool to process a sample
#define GO_HEALTH_TOOL_RUN_TIME_PERCENT (22019) ///< Average percentage of total time running the tool
#define GO_HEALTH_MEASUREMENT (30000) ///< Measurement value.
#define GO_HEALTH_MEASUREMENT_PASS (30001) ///< Number of pass decisions.
#define GO_HEALTH_MEASUREMENT_FAIL (30002) ///< Number of fail decisions.
#define GO_HEALTH_MEASUREMENT_MIN (30003) ///< Minimum measurement value.
#define GO_HEALTH_MEASUREMENT_MAX (30004) ///< Maximum measurement value.
#define GO_HEALTH_MEASUREMENT_AVERAGE (30005) ///< Average measurement value.
#define GO_HEALTH_MEASUREMENT_STDEV (30006) ///< Measurement value standard deviation.
#define GO_HEALTH_MEASUREMENT_INVALID_COUNT (30007) ///< Number of invalid values.
#define GO_HEALTH_MEASUREMENT_OVERFLOW_COUNT (30008) ///< Number of values which exceed the numerical limit of an output protocol's measurement value field.
/**@}*/
/**
* @struct GoIndicator
* @extends kValue
* @ingroup GoSdk-HealthChannel
* @brief Represents health indicator.
*/
typedef struct GoIndicator
{
k32u id; ///< Indicator ID (e.g. GO_HEALTH_CPU_USED)
k32u instance; ///< Indicator instance number.
k64s value; ///< Indicator value.
} GoIndicator;
/**
* @class GoHealthMsg
* @extends kObject
* @ingroup GoSdk-HealthChannel
* @brief Represents health information from a single sensor.
*/
typedef kObject GoHealthMsg;
/**
* Gets the health source.
*
* @public @memberof GoHealthMsg
* @version Introduced in firmware 4.0.10.27
* @param msg Message object.
* @return Health source.
*/
GoFx(GoDataSource) GoHealthMsg_Source(GoHealthMsg msg);
/**
* Count of health indicators in this message.
*
* @public @memberof GoHealthMsg
* @version Introduced in firmware 4.0.10.27
* @param msg Message object.
* @return Count of indicators.
*/
GoFx(kSize) GoHealthMsg_Count(GoHealthMsg msg);
/**
* Gets the health indicator at the specified index.
*
* @public @memberof GoHealthMsg
* @version Introduced in firmware 4.0.10.27
* @param msg Message object.
* @param index Indicator index.
* @return Indicator pointer.
*/
GoFx(GoIndicator*) GoHealthMsg_At(GoHealthMsg msg, kSize index);
/**
* Finds the health indicator with the matching ID. Returns kNULL if not found.
*
* @public @memberof GoHealthMsg
* @version Introduced in firmware 4.0.10.27
* @param msg Message object.
* @param id Indicator index.
* @param instance Indicator instance.
* @return Indicator pointer.
*/
GoFx(GoIndicator*) GoHealthMsg_Find(GoHealthMsg msg, k32u id, k32u instance);
#include <GoSdk/Messages/GoHealth.x.h>
#endif