Files
handleaiuinew/env/basler/include/pylon/_BaslerUniversalTLParams.h
2024-05-18 23:53:26 +08:00

4435 lines
222 KiB
C++

//-----------------------------------------------------------------------------
// Basler pylon SDK
// Copyright (c) 2019-2023 Basler AG
// http://www.baslerweb.com
//-----------------------------------------------------------------------------
/*!
\file
\brief A parameter class containing all parameters as members that are available for pylon device transport layers
The parameter class is used by the \c Pylon::CBaslerUniversalInstantCamera class.
The \ref sample_ParametrizeCamera_NativeParameterAccess code sample shows how to access camera parameters via the \c Pylon::CBaslerUniversalInstantCamera class.
*/
//-----------------------------------------------------------------------------
// This file is generated automatically
// Do not modify!
//-----------------------------------------------------------------------------
#ifndef BASLER_PYLON_UNIVERSALTLPARAMS_H
#define BASLER_PYLON_UNIVERSALTLPARAMS_H
#pragma once
// common parameter types
#include <pylon/ParameterIncludes.h>
#include <pylon/EnumParameterT.h>
namespace Basler_UniversalTLParams
{
//**************************************************************************************************
// Enumerations
//**************************************************************************************************
//! Valid values for AreaTriggerMode
enum AreaTriggerModeEnums
{
AreaTriggerMode_External, //!< The trigger mode is set to External - Applies to: CoaXPress
AreaTriggerMode_Generator, //!< The trigger mode is set to Generator - Applies to: CoaXPress
AreaTriggerMode_Software, //!< The trigger mode is set to Software - Applies to: CoaXPress
AreaTriggerMode_Synchronized //!< The trigger mode is set to Synchronized - Applies to: CoaXPress
};
//! Valid values for BitAlignment
enum BitAlignmentEnums
{
BitAlignment_CustomBitShift, //!< The bits are shifted by a user-defined value - Applies to: CoaXPress
BitAlignment_LeftAligned, //!< The bits left-aligned - Applies to: CoaXPress
BitAlignment_RightAligned //!< The bits right-aligned - Applies to: CoaXPress
};
//! Valid values for CxpLinkConfiguration
enum CxpLinkConfigurationEnums
{
CxpLinkConfiguration_Auto, //!< Link speed is controlled automatically - Applies to: CoaXPress
CxpLinkConfiguration_CXP10_X1, //!< 1 connection is operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP10_X2, //!< 2 connections are operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP10_X3, //!< 3 connections are operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP10_X4, //!< 4 connections are operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP12_X1, //!< 1 connection is operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP12_X2, //!< 2 connections are operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP12_X3, //!< 3 connections are operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP12_X4, //!< 4 connections are operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP1_X1, //!< 1 connection is operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP1_X2, //!< 2 connections are operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP1_X3, //!< 3 connections are operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP1_X4, //!< 4 connections are operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP2_X1, //!< 1 connection is operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP2_X2, //!< 2 connections are operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP2_X3, //!< 3 connections are operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP2_X4, //!< 4 connections are operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP3_X1, //!< 1 connection is operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP3_X2, //!< 2 connections are operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP3_X3, //!< 3 connections are operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP3_X4, //!< 4 connections are operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP5_X1, //!< 1 connection is operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP5_X2, //!< 2 connections are operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP5_X3, //!< 3 connections are operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP5_X4, //!< 4 connections are operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP6_X1, //!< 1 connection is operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP6_X2, //!< 2 connections are operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP6_X3, //!< 3 connections are operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress
CxpLinkConfiguration_CXP6_X4 //!< 4 connections are operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress
};
//! Valid values for CxpTriggerPacketMode
enum CxpTriggerPacketModeEnums
{
CxpTriggerPacketMode_CXPTriggerRising, //!< Only rising edge trigger packets are sent - Applies to: CoaXPress
CxpTriggerPacketMode_CXPTriggerStandard //!< Rising and falling edge trigger packets are sent on an alternating basis - Applies to: CoaXPress
};
//! Valid values for DeviceAccessStatus
enum DeviceAccessStatusEnums
{
DeviceAccessStatus_Busy, //!< The device is already opened by another entity - Applies to: CoaXPress and blaze
DeviceAccessStatus_NoAccess, //!< You can't connect to the device - Applies to: CoaXPress and blaze
DeviceAccessStatus_OpenReadOnly, //!< The device is opened in Read-only mode by this GenTL host - Applies to: CoaXPress and blaze
DeviceAccessStatus_OpenReadWrite, //!< The device is opened in Read/Write mode by this GenTL host - Applies to: CoaXPress and blaze
DeviceAccessStatus_ReadOnly, //!< The device offers read-only access - Applies to: CoaXPress and blaze
DeviceAccessStatus_ReadWrite, //!< The device offers read/write access - Applies to: CoaXPress and blaze
DeviceAccessStatus_Unknown //!< The status is unknown - Applies to: CoaXPress and blaze
};
//! Valid values for DeviceEndianessMechanism
enum DeviceEndianessMechanismEnums
{
DeviceEndianessMechanism_Legacy, //!< The device endianness is handled according to GenICam Schema 1 0 - Applies to: blaze
DeviceEndianessMechanism_Standard //!< The device endianness is handled according to GenICam Schema 1 1 and later - Applies to: blaze
};
//! Valid values for DeviceType
enum DeviceTypeEnums
{
DeviceType_CL, //!< The device uses the Camera Link transport layer - Applies to: CoaXPress
DeviceType_CLHS, //!< The device uses the Camera Link HS transport layer - Applies to: CoaXPress
DeviceType_CXP, //!< The device uses the CoaXPress transport layer - Applies to: CoaXPress
DeviceType_CameraLink, //!< Camera Link - Applies to: CoaXPress
DeviceType_CameraLinkHS, //!< Camera Link High Speed - Applies to: CoaXPress
DeviceType_CoaXPress, //!< CoaXPress - Applies to: CoaXPress
DeviceType_Custom, //!< The device uses a custom transport layer - Applies to: CoaXPress
DeviceType_GEV, //!< The device uses the GigE Vision transport layer - Applies to: CoaXPress
DeviceType_GigEVision, //!< GigE Vision - Applies to: CoaXPress
DeviceType_Mixed, //!< Different interface modules of the GenTL Producer are of different types - Applies to: CoaXPress
DeviceType_U3V, //!< The device uses the USB3 Vision transport layer - Applies to: CoaXPress
DeviceType_USB3Vision //!< USB3 Vision - Applies to: CoaXPress
};
//! Valid values for EventNotification
enum EventNotificationEnums
{
EventNotification_Off, //!< The selected event notification is disabled - Applies to: CoaXPress and blaze
EventNotification_On, //!< The selected event notification is enabled - Applies to: CoaXPress and blaze
EventNotification_Once //!< The selected event notification is enabled for one event and then returned to Off state - Applies to: CoaXPress and blaze
};
//! Valid values for EventSelector
enum EventSelectorEnums
{
EventSelector_AcquisitionTrigger, //!< Entry for the event AcquisitionTrigger - Applies to: CoaXPress
EventSelector_DeviceLost, //!< The Device Lost event is selected - Applies to: CoaXPress and blaze
EventSelector_FrameTransferEnd, //!< Entry for the event FrameTransferEnd - Applies to: CoaXPress
EventSelector_FrameTransferStart, //!< Entry for the event FrameTransferStart - Applies to: CoaXPress
EventSelector_FrameTriggerMissed, //!< Entry for the event FrameTriggerMissed - Applies to: CoaXPress
EventSelector_Overflow, //!< Entry for the event Overflow - Applies to: CoaXPress
EventSelector_TriggerExceededPeriodLimits, //!< Entry for the event TriggerExceededPeriodLimits - Applies to: CoaXPress
EventSelector_TriggerQueueFilllevelThresholdOff, //!< Entry for the event TriggerQueueFilllevelThresholdOff - Applies to: CoaXPress
EventSelector_TriggerQueueFilllevelThresholdOn //!< Entry for the event TriggerQueueFilllevelThresholdOn - Applies to: CoaXPress
};
//! Valid values for Format
enum FormatEnums
{
Format_BGR10p, //!< The pixel output format is set to BGR10p - Applies to: CoaXPress
Format_BGR12p, //!< The pixel output format is set to BGR12p - Applies to: CoaXPress
Format_BGR14p, //!< The pixel output format is set to BGR14p - Applies to: CoaXPress
Format_BGR16, //!< The pixel output format is set to BGR16 - Applies to: CoaXPress
Format_BGR8, //!< The pixel output format is set to BGR8 - Applies to: CoaXPress
Format_BGRa8, //!< The pixel output format is set to BGRa8 - Applies to: CoaXPress
Format_BayerBG10p, //!< The pixel output format is set to BayerBG10p - Applies to: CoaXPress
Format_BayerBG12p, //!< The pixel output format is set to BayerBG12p - Applies to: CoaXPress
Format_BayerBG14p, //!< The pixel output format is set to BayerBG14p - Applies to: CoaXPress
Format_BayerBG16, //!< The pixel output format is set to BayerBG16 - Applies to: CoaXPress
Format_BayerBG8, //!< The pixel output format is set to BayerBG8 - Applies to: CoaXPress
Format_BayerGB10p, //!< The pixel output format is set to BayerGB10p - Applies to: CoaXPress
Format_BayerGB12p, //!< The pixel output format is set to BayerGB12p - Applies to: CoaXPress
Format_BayerGB14p, //!< The pixel output format is set to BayerGB14p - Applies to: CoaXPress
Format_BayerGB16, //!< The pixel output format is set to BayerGB16 - Applies to: CoaXPress
Format_BayerGB8, //!< The pixel output format is set to BayerGB8 - Applies to: CoaXPress
Format_BayerGR10p, //!< The pixel output format is set to BayerGR10p - Applies to: CoaXPress
Format_BayerGR12p, //!< The pixel output format is set to BayerGR12p - Applies to: CoaXPress
Format_BayerGR14p, //!< The pixel output format is set to BayerGR14p - Applies to: CoaXPress
Format_BayerGR16, //!< The pixel output format is set to BayerGR16 - Applies to: CoaXPress
Format_BayerGR8, //!< The pixel output format is set to BayerGR8 - Applies to: CoaXPress
Format_BayerRG10p, //!< The pixel output format is set to BayerRG10p - Applies to: CoaXPress
Format_BayerRG12p, //!< The pixel output format is set to BayerRG12p - Applies to: CoaXPress
Format_BayerRG14p, //!< The pixel output format is set to BayerRG14p - Applies to: CoaXPress
Format_BayerRG16, //!< The pixel output format is set to BayerRG16 - Applies to: CoaXPress
Format_BayerRG8, //!< The pixel output format is set to BayerRG8 - Applies to: CoaXPress
Format_Mono10p, //!< The pixel output format is set to Mono10p - Applies to: CoaXPress
Format_Mono12p, //!< The pixel output format is set to Mono12p - Applies to: CoaXPress
Format_Mono14p, //!< The pixel output format is set to Mono14p - Applies to: CoaXPress
Format_Mono16, //!< The pixel output format is set to Mono16 - Applies to: CoaXPress
Format_Mono8, //!< The pixel output format is set to Mono8 - Applies to: CoaXPress
Format_RGB10p, //!< The pixel output format is set to RGB10p - Applies to: CoaXPress
Format_RGB12p, //!< The pixel output format is set to RGB12p - Applies to: CoaXPress
Format_RGB14p, //!< The pixel output format is set to RGB14p - Applies to: CoaXPress
Format_RGB16, //!< The pixel output format is set to RGB16 - Applies to: CoaXPress
Format_RGB8, //!< The pixel output format is set to RGB8 - Applies to: CoaXPress
Format_RGBa8, //!< The pixel output format is set to RGBa8 - Applies to: CoaXPress
Format_YCbCr422_8 //!< The pixel output format is set to YCbCr422_8 - Applies to: CoaXPress
};
//! Valid values for LutEnable
enum LutEnableEnums
{
LutEnable_Off, //!< The trigger queue mode is disabled - Applies to: CoaXPress
LutEnable_On //!< The trigger queue mode is enabled - Applies to: CoaXPress
};
//! Valid values for LutImplementationType
enum LutImplementationTypeEnums
{
LutImplementationType_FullLUT, //!< Defines 1 value for each possible pixel value - Applies to: CoaXPress
LutImplementationType_KneeLUT //!< Uses an interpolation for pixel values based one a set of defined values - Applies to: CoaXPress
};
//! Valid values for LutType
enum LutTypeEnums
{
LutType_Processor, //!< Processor - Applies to: CoaXPress
LutType_UserFile //!< Use a user file to configure the value - Applies to: CoaXPress
};
//! Valid values for MissingCameraFrameResponse
enum MissingCameraFrameResponseEnums
{
MissingCameraFrameResponse_No, //!< The camera sends a frame for each output trigger pulse - Applies to: CoaXPress
MissingCameraFrameResponse_Yes //!< The camera doesn't send a frame for each output trigger pulse - Applies to: CoaXPress
};
//! Valid values for OverflowEventSelect
enum OverflowEventSelectEnums
{
OverflowEventSelect_All, //!< All - Applies to: CoaXPress
OverflowEventSelect_Incomplete, //!< Incomplete - Applies to: CoaXPress
OverflowEventSelect_IncompleteLost, //!< IncompleteLost - Applies to: CoaXPress
OverflowEventSelect_IncompleteOK, //!< IncompleteOK - Applies to: CoaXPress
OverflowEventSelect_Lost, //!< Lost - Applies to: CoaXPress
OverflowEventSelect_LostOK, //!< LostOK - Applies to: CoaXPress
OverflowEventSelect_OK //!< OK - Applies to: CoaXPress
};
//! Valid values for PixelFormat
enum PixelFormatEnums
{
PixelFormat_BayerBG10p, //!< The pixel format is set to BayerBG10p - Applies to: CoaXPress
PixelFormat_BayerBG12p, //!< The pixel format is set to BayerBG12p - Applies to: CoaXPress
PixelFormat_BayerBG14p, //!< The pixel format is set to BayerBG14p - Applies to: CoaXPress
PixelFormat_BayerBG8, //!< The pixel format is set to BayerBG8 - Applies to: CoaXPress
PixelFormat_BayerGB10p, //!< The pixel format is set to BayerGB10p - Applies to: CoaXPress
PixelFormat_BayerGB12p, //!< The pixel format is set to BayerGB12p - Applies to: CoaXPress
PixelFormat_BayerGB14p, //!< The pixel format is set to BayerGB14p - Applies to: CoaXPress
PixelFormat_BayerGB8, //!< The pixel format is set to BayerGB8 - Applies to: CoaXPress
PixelFormat_BayerGR10p, //!< The pixel format is set to BayerGR10p - Applies to: CoaXPress
PixelFormat_BayerGR12p, //!< The pixel format is set to BayerGR12p - Applies to: CoaXPress
PixelFormat_BayerGR14p, //!< The pixel format is set to BayerGR14p - Applies to: CoaXPress
PixelFormat_BayerGR8, //!< The pixel format is set to BayerGR8 - Applies to: CoaXPress
PixelFormat_BayerRG10p, //!< The pixel format is set to BayerRG10p - Applies to: CoaXPress
PixelFormat_BayerRG12p, //!< The pixel format is set to BayerRG12p - Applies to: CoaXPress
PixelFormat_BayerRG14p, //!< The pixel format is set to BayerRG14p - Applies to: CoaXPress
PixelFormat_BayerRG8, //!< The pixel format is set to BayerRG8 - Applies to: CoaXPress
PixelFormat_Mono10, //!< The pixel format is set to Mono10 - Applies to: CoaXPress
PixelFormat_Mono10p, //!< The pixel output format is set to Mono10p - Applies to: CoaXPress
PixelFormat_Mono12, //!< The pixel format is set to Mono12 - Applies to: CoaXPress
PixelFormat_Mono12p, //!< The pixel output format is set to Mono12p - Applies to: CoaXPress
PixelFormat_Mono14p, //!< The pixel output format is set to Mono14p - Applies to: CoaXPress
PixelFormat_Mono16, //!< The pixel format is set to Mono16 - Applies to: CoaXPress
PixelFormat_Mono8, //!< The pixel format is set to Mono8 - Applies to: CoaXPress
PixelFormat_RGB10p, //!< The pixel format is set to RGB10p - Applies to: CoaXPress
PixelFormat_RGB12p, //!< The pixel format is set to RGB12p - Applies to: CoaXPress
PixelFormat_RGB14p, //!< The pixel format is set to RGB14p - Applies to: CoaXPress
PixelFormat_RGB16, //!< The pixel format is set to RGB16 - Applies to: CoaXPress
PixelFormat_RGB8, //!< The pixel format is set to RGB8 - Applies to: CoaXPress
PixelFormat_YCbCr422_8 //!< The pixel format is set to YCbCr422_8 - Applies to: CoaXPress
};
//! Valid values for ProcessingInvert
enum ProcessingInvertEnums
{
ProcessingInvert_Off, //!< The trigger queue mode is disabled - Applies to: CoaXPress
ProcessingInvert_On //!< The trigger queue mode is enabled - Applies to: CoaXPress
};
//! Valid values for SoftwareTriggerIsBusy
enum SoftwareTriggerIsBusyEnums
{
SoftwareTriggerIsBusy_Busy, //!< The software trigger is busy - Applies to: CoaXPress
SoftwareTriggerIsBusy_NotBusy //!< The software trigger is not busy - Applies to: CoaXPress
};
//! Valid values for SystemmonitorByteAlignment8b10bLocked
enum SystemmonitorByteAlignment8b10bLockedEnums
{
SystemmonitorByteAlignment8b10bLocked_No, //!< No - Applies to: CoaXPress
SystemmonitorByteAlignment8b10bLocked_Yes //!< Yes - Applies to: CoaXPress
};
//! Valid values for SystemmonitorExternalPower
enum SystemmonitorExternalPowerEnums
{
SystemmonitorExternalPower_NoPower, //!< No power - Applies to: CoaXPress
SystemmonitorExternalPower_PowerGood //!< Power is ok - Applies to: CoaXPress
};
//! Valid values for SystemmonitorPowerOverCxpState
enum SystemmonitorPowerOverCxpStateEnums
{
SystemmonitorPowerOverCxpState_PoCXPADCChipError, //!< ADC Chip Error - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPBooting, //!< Booting, not initalized - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPDisabled, //!< No Power over CXP - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPLowVolt, //!< Low voltage - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPMaxCurrent, //!< Maximum current - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPMinCurrent, //!< Minimum current - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPNotConnected, //!< No cable connected - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPOK, //!< Power over CXP OK - Applies to: CoaXPress
SystemmonitorPowerOverCxpState_PoCXPOverVolt //!< Over voltage - Applies to: CoaXPress
};
//! Valid values for TriggerCameraOutSelect
enum TriggerCameraOutSelectEnums
{
TriggerCameraOutSelect_BypassFrontGPI0, //!< The output source is set to BypassFrontGPI0 - Applies to: CoaXPress
TriggerCameraOutSelect_BypassFrontGPI1, //!< The output source is set to BypassFrontGPI1 - Applies to: CoaXPress
TriggerCameraOutSelect_BypassFrontGPI2, //!< The output source is set to BypassFrontGPI2 - Applies to: CoaXPress
TriggerCameraOutSelect_BypassFrontGPI3, //!< The output source is set to BypassFrontGPI3 - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_CamAPulseGenerator0, //!< The output source is set to CamAPulseGenerator0 - Applies to: CoaXPress
TriggerCameraOutSelect_CamAPulseGenerator1, //!< The output source is set to CamAPulseGenerator1 - Applies to: CoaXPress
TriggerCameraOutSelect_CamAPulseGenerator2, //!< The output source is set to CamAPulseGenerator2 - Applies to: CoaXPress
TriggerCameraOutSelect_CamAPulseGenerator3, //!< The output source is set to CamAPulseGenerator3 - Applies to: CoaXPress
TriggerCameraOutSelect_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerCameraOutSelect_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerCameraOutSelect_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerCameraOutSelect_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerCameraOutSelect_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerCameraOutSelect_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerCameraOutSelect_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerCameraOutSelect_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerCameraOutSelect_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerCameraOutSelect_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerCameraOutSelect_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerCameraOutSelect_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerCameraOutSelect_GND, //!< The output source is set to GND - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFronGPI0, //!< The output source is set to NotBypassFrontGPI0 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFronGPI1, //!< The output source is set to NotBypassFrontGPI1 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFronGPI2, //!< The output source is set to NotBypassFrontGPI2 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFronGPI3, //!< The output source is set to NotBypassFrontGPI3 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamAPulseGenerator0, //!< The output source is set to NotCamAPulseGenerator0 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamAPulseGenerator1, //!< The output source is set to NotCamAPulseGenerator1 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamAPulseGenerator2, //!< The output source is set to NotCamAPulseGenerator2 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamAPulseGenerator3, //!< The output source is set to NotCamAPulseGenerator3 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerCameraOutSelect_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerCameraOutSelect_NotPulseGenerator0, //!< The output source is set to NotPulseGenerator0 - Applies to: CoaXPress
TriggerCameraOutSelect_NotPulseGenerator1, //!< The output source is set to NotPulseGenerator1 - Applies to: CoaXPress
TriggerCameraOutSelect_NotPulseGenerator2, //!< The output source is set to NotPulseGenerator2 - Applies to: CoaXPress
TriggerCameraOutSelect_NotPulseGenerator3, //!< The output source is set to NotPulseGenerator3 - Applies to: CoaXPress
TriggerCameraOutSelect_PulseGenerator0, //!< The output source is set to PulseGenerator0 - Applies to: CoaXPress
TriggerCameraOutSelect_PulseGenerator1, //!< The output source is set to PulseGenerator1 - Applies to: CoaXPress
TriggerCameraOutSelect_PulseGenerator2, //!< The output source is set to PulseGenerator2 - Applies to: CoaXPress
TriggerCameraOutSelect_PulseGenerator3, //!< The output source is set to PulseGenerator3 - Applies to: CoaXPress
TriggerCameraOutSelect_VCC //!< The output source is set to VCC - Applies to: CoaXPress
};
//! Valid values for TriggerExceededPeriodLimits
enum TriggerExceededPeriodLimitsEnums
{
TriggerExceededPeriodLimits_No, //!< The input signal frequency hasn't exceeded the maximum frequency defined by the Trigger Output Frequency parameter - Applies to: CoaXPress
TriggerExceededPeriodLimits_Yes //!< The input signal frequency has exceeded the maximum frequency defined by the Trigger Output Frequency parameter - Applies to: CoaXPress
};
//! Valid values for TriggerInPolarity
enum TriggerInPolarityEnums
{
TriggerInPolarity_HighActive, //!< The polarity is set to HighActive - Applies to: CoaXPress
TriggerInPolarity_LowActive //!< The polarity is set to LowActive - Applies to: CoaXPress
};
//! Valid values for TriggerInSource
enum TriggerInSourceEnums
{
TriggerInSource_GPITriggerSource0, //!< GPI Trigger Source 0 - Applies to: CoaXPress
TriggerInSource_GPITriggerSource1, //!< GPI Trigger Source 1 - Applies to: CoaXPress
TriggerInSource_GPITriggerSource2, //!< GPI Trigger Source 2 - Applies to: CoaXPress
TriggerInSource_GPITriggerSource3, //!< GPI Trigger Source 3 - Applies to: CoaXPress
TriggerInSource_GPITriggerSource4, //!< GPI Trigger Source 4 - Applies to: CoaXPress
TriggerInSource_GPITriggerSource5, //!< GPI Trigger Source 5 - Applies to: CoaXPress
TriggerInSource_GPITriggerSource6, //!< GPI Trigger Source 6 - Applies to: CoaXPress
TriggerInSource_GPITriggerSource7, //!< GPI Trigger Source 7 - Applies to: CoaXPress
TriggerInSource_TriggerInSourceFrontGPI0, //!< The trigger input source is set to TriggerInSourceFrontGPI0 - Applies to: CoaXPress
TriggerInSource_TriggerInSourceFrontGPI1, //!< The trigger input source is set to TriggerInSourceFrontGPI1 - Applies to: CoaXPress
TriggerInSource_TriggerInSourceFrontGPI2, //!< The trigger input source is set to TriggerInSourceFrontGPI2 - Applies to: CoaXPress
TriggerInSource_TriggerInSourceFrontGPI3 //!< The trigger input source is set to TriggerInSourceFrontGPI3 - Applies to: CoaXPress
};
//! Valid values for TriggerInStatisticsPolarity
enum TriggerInStatisticsPolarityEnums
{
TriggerInStatisticsPolarity_HighActive, //!< The trigger polarity of the input specified by the Statistics Source parameter is set to High Active - Applies to: CoaXPress
TriggerInStatisticsPolarity_LowActive //!< The trigger polarity of the input specified by the Statistics Source parameter is set to Low Active - Applies to: CoaXPress
};
//! Valid values for TriggerInStatisticsSource
enum TriggerInStatisticsSourceEnums
{
TriggerInStatisticsSource_GPITriggerSource0, //!< GPI Trigger Source 0 - Applies to: CoaXPress
TriggerInStatisticsSource_GPITriggerSource1, //!< GPI Trigger Source 1 - Applies to: CoaXPress
TriggerInStatisticsSource_GPITriggerSource2, //!< GPI Trigger Source 2 - Applies to: CoaXPress
TriggerInStatisticsSource_GPITriggerSource3, //!< GPI Trigger Source 3 - Applies to: CoaXPress
TriggerInStatisticsSource_GPITriggerSource4, //!< GPI Trigger Source 4 - Applies to: CoaXPress
TriggerInStatisticsSource_GPITriggerSource5, //!< GPI Trigger Source 5 - Applies to: CoaXPress
TriggerInStatisticsSource_GPITriggerSource6, //!< GPI Trigger Source 6 - Applies to: CoaXPress
TriggerInStatisticsSource_GPITriggerSource7, //!< GPI Trigger Source 7 - Applies to: CoaXPress
TriggerInStatisticsSource_TriggerInSourceFrontGPI0, //!< The input source of the trigger statistics is set to Front GPI Trigger Source 0 - Applies to: CoaXPress
TriggerInStatisticsSource_TriggerInSourceFrontGPI1, //!< The input source of the trigger statistics is set to Front GPI Trigger Source 1 - Applies to: CoaXPress
TriggerInStatisticsSource_TriggerInSourceFrontGPI2, //!< The input source of the trigger statistics is set to Front GPI Trigger Source 2 - Applies to: CoaXPress
TriggerInStatisticsSource_TriggerInSourceFrontGPI3 //!< The input source of the trigger statistics is set to Front GPI Trigger Source 3 - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectFrontGPO0
enum TriggerOutSelectFrontGPO0Enums
{
TriggerOutSelectFrontGPO0_BypassFrontGPI0, //!< The output source is set to BypassFrontGPI0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassFrontGPI1, //!< The output source is set to BypassFrontGPI1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassFrontGPI2, //!< The output source is set to BypassFrontGPI2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassFrontGPI3, //!< The output source is set to BypassFrontGPI3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamAPulseGenerator0, //!< The output source is set to CamAPulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamAPulseGenerator1, //!< The output source is set to CamAPulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamAPulseGenerator2, //!< The output source is set to CamAPulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamAPulseGenerator3, //!< The output source is set to CamAPulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_GND, //!< The output source is set to GND - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFronGPI0, //!< The output source is set to NotBypassFrontGPI0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFronGPI1, //!< The output source is set to NotBypassFrontGPI1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFronGPI2, //!< The output source is set to NotBypassFrontGPI2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFronGPI3, //!< The output source is set to NotBypassFrontGPI3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator0, //!< The output source is set to NotCamAPulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator1, //!< The output source is set to NotCamAPulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator2, //!< The output source is set to NotCamAPulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator3, //!< The output source is set to NotCamAPulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotPulseGenerator0, //!< The output source is set to NotPulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotPulseGenerator1, //!< The output source is set to NotPulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotPulseGenerator2, //!< The output source is set to NotPulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_NotPulseGenerator3, //!< The output source is set to NotPulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_PulseGenerator0, //!< The output source is set to PulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_PulseGenerator1, //!< The output source is set to PulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_PulseGenerator2, //!< The output source is set to PulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_PulseGenerator3, //!< The output source is set to PulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO0_VCC //!< The output source is set to VCC - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectFrontGPO1
enum TriggerOutSelectFrontGPO1Enums
{
TriggerOutSelectFrontGPO1_BypassFrontGPI0, //!< The output source is set to BypassFrontGPI0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassFrontGPI1, //!< The output source is set to BypassFrontGPI1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassFrontGPI2, //!< The output source is set to BypassFrontGPI2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassFrontGPI3, //!< The output source is set to BypassFrontGPI3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamAPulseGenerator0, //!< The output source is set to CamAPulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamAPulseGenerator1, //!< The output source is set to CamAPulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamAPulseGenerator2, //!< The output source is set to CamAPulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamAPulseGenerator3, //!< The output source is set to CamAPulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_GND, //!< The output source is set to GND - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFronGPI0, //!< The output source is set to NotBypassFrontGPI0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFronGPI1, //!< The output source is set to NotBypassFrontGPI1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFronGPI2, //!< The output source is set to NotBypassFrontGPI2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFronGPI3, //!< The output source is set to NotBypassFrontGPI3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator0, //!< The output source is set to NotCamAPulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator1, //!< The output source is set to NotCamAPulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator2, //!< The output source is set to NotCamAPulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator3, //!< The output source is set to NotCamAPulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotPulseGenerator0, //!< The output source is set to NotPulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotPulseGenerator1, //!< The output source is set to NotPulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotPulseGenerator2, //!< The output source is set to NotPulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_NotPulseGenerator3, //!< The output source is set to NotPulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_PulseGenerator0, //!< The output source is set to PulseGenerator0 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_PulseGenerator1, //!< The output source is set to PulseGenerator1 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_PulseGenerator2, //!< The output source is set to PulseGenerator2 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_PulseGenerator3, //!< The output source is set to PulseGenerator3 - Applies to: CoaXPress
TriggerOutSelectFrontGPO1_VCC //!< The output source is set to VCC - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO0
enum TriggerOutSelectGPO0Enums
{
TriggerOutSelectGPO0_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO0_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO0_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO0_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO0_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO1
enum TriggerOutSelectGPO1Enums
{
TriggerOutSelectGPO1_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO1_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO1_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO1_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO1_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO2
enum TriggerOutSelectGPO2Enums
{
TriggerOutSelectGPO2_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO2_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO2_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO2_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO2_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO3
enum TriggerOutSelectGPO3Enums
{
TriggerOutSelectGPO3_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO3_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO3_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO3_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO3_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO4
enum TriggerOutSelectGPO4Enums
{
TriggerOutSelectGPO4_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO4_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO4_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO4_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO4_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO5
enum TriggerOutSelectGPO5Enums
{
TriggerOutSelectGPO5_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO5_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO5_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO5_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO5_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO6
enum TriggerOutSelectGPO6Enums
{
TriggerOutSelectGPO6_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO6_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO6_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO6_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO6_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutSelectGPO7
enum TriggerOutSelectGPO7Enums
{
TriggerOutSelectGPO7_BypassFrontGPI0, //!< Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassFrontGPI1, //!< Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassFrontGPI2, //!< Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassFrontGPI3, //!< Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI0, //!< Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI1, //!< Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI2, //!< Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI3, //!< Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI4, //!< Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI5, //!< Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI6, //!< Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_BypassGPI7, //!< Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_CamAPulseGenerator0, //!< Camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamAPulseGenerator1, //!< Camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamAPulseGenerator2, //!< Camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamAPulseGenerator3, //!< Camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamBPulseGenerator0, //!< The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamBPulseGenerator1, //!< The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamBPulseGenerator2, //!< The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamBPulseGenerator3, //!< The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamCPulseGenerator0, //!< The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamCPulseGenerator1, //!< The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamCPulseGenerator2, //!< The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamCPulseGenerator3, //!< The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamDPulseGenerator0, //!< The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamDPulseGenerator1, //!< The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamDPulseGenerator2, //!< The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_CamDPulseGenerator3, //!< The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_GND, //!< A static zero - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassFrontGPI0, //!< The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassFrontGPI1, //!< The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassFrontGPI2, //!< The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassFrontGPI3, //!< The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI0, //!< Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI1, //!< Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI2, //!< Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI3, //!< Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI4, //!< Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI5, //!< Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI6, //!< Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotBypassGPI7, //!< Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamAPulseGenerator0, //!< Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamAPulseGenerator1, //!< Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamAPulseGenerator2, //!< Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamAPulseGenerator3, //!< Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamBPulseGenerator0, //!< The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamBPulseGenerator1, //!< The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamBPulseGenerator2, //!< The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamBPulseGenerator3, //!< The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamCPulseGenerator0, //!< The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamCPulseGenerator1, //!< The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamCPulseGenerator2, //!< The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamCPulseGenerator3, //!< The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamDPulseGenerator0, //!< The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamDPulseGenerator1, //!< The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamDPulseGenerator2, //!< The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotCamDPulseGenerator3, //!< The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotPulseGenerator0, //!< Inverted signal of pulse generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotPulseGenerator1, //!< Inverted signal of pulse generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotPulseGenerator2, //!< Inverted signal of pulse generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_NotPulseGenerator3, //!< Inverted signal of pulse generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutSelectGPO7_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutSelectGPO7_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutSelectGPO7_PulseGenerator3, //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
TriggerOutSelectGPO7_VCC //!< A static one - Applies to: CoaXPress
};
//! Valid values for TriggerOutStatisticsSource
enum TriggerOutStatisticsSourceEnums
{
TriggerOutStatisticsSource_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutStatisticsSource_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutStatisticsSource_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutStatisticsSource_PulseGenerator3 //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
};
//! Valid values for TriggerOutputEventSelect
enum TriggerOutputEventSelectEnums
{
TriggerOutputEventSelect_PulseGenerator0, //!< The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress
TriggerOutputEventSelect_PulseGenerator1, //!< The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress
TriggerOutputEventSelect_PulseGenerator2, //!< The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress
TriggerOutputEventSelect_PulseGenerator3 //!< The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress
};
//! Valid values for TriggerQueueMode
enum TriggerQueueModeEnums
{
TriggerQueueMode_Off, //!< The trigger queue mode is disabled - Applies to: CoaXPress
TriggerQueueMode_On //!< The trigger queue mode is enabled - Applies to: CoaXPress
};
//! Valid values for TriggerState
enum TriggerStateEnums
{
TriggerState_Active, //!< The trigger state is set to Active - Applies to: CoaXPress
TriggerState_AsyncStop, //!< The trigger state is set to AsyncStop - Applies to: CoaXPress
TriggerState_SyncStop //!< The trigger state is set to SyncStop - Applies to: CoaXPress
};
//! Valid values for VantagePoint
enum VantagePointEnums
{
VantagePoint_BottomLeft, //!< Starting point of the image is the bottom left corner - Applies to: CoaXPress
VantagePoint_BottomRight, //!< Starting point of the image is the bottom right corner - Applies to: CoaXPress
VantagePoint_TopLeft, //!< Starting point of the image is the top left corner - Applies to: CoaXPress
VantagePoint_TopRight //!< Starting point of the image is the top right corner - Applies to: CoaXPress
};
//**************************************************************************************************
// Parameter class CUniversalTLParams_Params_v7_3_0
//**************************************************************************************************
/*!
\brief A parameter class containing all parameters as members that are available for pylon device transport layers
The parameter class is used by the \c Pylon::CBaslerUniversalInstantCamera class.
The \ref sample_ParametrizeCamera_NativeParameterAccess code sample shows how to access camera parameters via the \c Pylon::CBaslerUniversalInstantCamera class.
*/
class PYLONBASE_API CUniversalTLParams_Params_v7_3_0
{
//----------------------------------------------------------------------------------------------------------------
// Implementation
//----------------------------------------------------------------------------------------------------------------
protected:
// If you want to show the following methods in the help file
// add the string HIDE_CLASS_METHODS to the ENABLED_SECTIONS tag in the doxygen file
//! \cond HIDE_CLASS_METHODS
//! Constructor
CUniversalTLParams_Params_v7_3_0( void );
//! Destructor
~CUniversalTLParams_Params_v7_3_0( void );
//! Initializes the references
void _Initialize( GENAPI_NAMESPACE::INodeMap* );
//! \endcond
private:
class CUniversalTLParams_Params_v7_3_0_Data;
CUniversalTLParams_Params_v7_3_0_Data* m_pCUniversalTLParams_Params_v7_3_0_Data;
//----------------------------------------------------------------------------------------------------------------
// References to features
//----------------------------------------------------------------------------------------------------------------
public:
//! \name Categories: Trigger
//@{
/*!
\brief Sets the trigger mode of the area trigger signal - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=AreaTriggerMode" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<AreaTriggerModeEnums>& AreaTriggerMode;
//@}
//! \name Categories: ImageFormatControl
//@{
/*!
\brief Enables/disables automatic control of the pixel format in the device - Applies to: CoaXPress
Enables/disables automatic control of the pixel format in the device. If enabled, the frame grabber's pixel format and its dependencies are automatically updated to match the camera's pixel format setting.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=AutomaticFormatControl" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& AutomaticFormatControl;
//@}
//! \name Categories: ImageFormatControl
//@{
/*!
\brief Activates or deactivates the automatic control of the ROI in the Device - Applies to: CoaXPress
Activates or deactivates the automatic control of the ROI in the Device. If this feature is active, the frame grabber ROI is automatically updated to the camera one.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=AutomaticROIControl" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& AutomaticROIControl;
//@}
//! \name Categories: OutputFormat
//@{
/*!
\brief Sets the alignment of the bits in the output format - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=BitAlignment" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<BitAlignmentEnums>& BitAlignment;
//@}
//! \name Categories: ExtendedDeviceControl and Root
//@{
/*!
\brief Enables sending all commands and receiving all acknowledges twice - Applies to: GigE and blaze
Enables sending all commands and receiving all acknowledges twice. This option should only be enabled in case of network problems.
Visibility: Guru
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=CommandDuplicationEnable" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& CommandDuplicationEnable;
//@}
//! \name Categories: Root
//@{
/*!
\brief Enables the automatic start of the PylonGigEConnectionGuard - Applies to: GigE
Visibility: Guru
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ConnectionGuardEnable" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& ConnectionGuardEnable;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Number of errors corrected - Applies to: CoaXPress
Number of errors corrected. This parameter indicates single-byte error correction in CXP stream packets.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=CorrectedErrorCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& CorrectedErrorCount;
//@}
//! \name Categories: OutputFormat
//@{
/*!
\brief User-defined bit shift to the right - Applies to: CoaXPress
User-defined bit shift to the right. This allows you to shift the pixel data in the output format to the right by a value of your choice. The Alignment parameter has to be set to CustomBitShift for this.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=CustomBitShiftRight" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& CustomBitShiftRight;
//@}
//! \name Categories: TransportLayerControl
//@{
/*!
\brief Sets the link configuration for the communication between the receiver and transmitter device - Applies to: CoaXPress
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=CxpLinkConfiguration" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<CxpLinkConfigurationEnums>& CxpLinkConfiguration;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Sets the trigger packet mode - Applies to: CoaXPress
Sets the trigger packet mode. This parameter allows you to send triggers on rising edges only. It can be used for extreme trigger rates. This parameter may violate the CXP standard.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=CxpTriggerPacketMode" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<CxpTriggerPacketModeEnums>& CxpTriggerPacketMode;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Returns the device's access status at the moment when the Device Update List command was last executed - Applies to: CoaXPress and blaze
Returns the device's access status at the moment when the Device Update List command was last executed. This value only changes when the Device Update List command is executed.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceAccessStatus" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<DeviceAccessStatusEnums>& DeviceAccessStatus;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief User-friendly name of the device - Applies to: CoaXPress and blaze
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceDisplayName" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& DeviceDisplayName;
//@}
//! \name Categories: DeviceControl
//@{
/*!
\brief Sets the endianness handling mode - Applies to: blaze
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceEndianessMechanism" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<DeviceEndianessMechanismEnums>& DeviceEndianessMechanism;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Interface-wide unique ID of the selected device - Applies to: CoaXPress and blaze
Interface-wide unique ID of the selected device. This value only changes when the Device Update List command is executed.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceID" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& DeviceID;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Additional information about the manufacturer of the device - Applies to: blaze
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceManufacturerInfo" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& DeviceManufacturerInfo;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Name of the device model - Applies to: CoaXPress and blaze
Name of the device model. This value only changes when the Device Update List command is executed.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceModelName" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& DeviceModelName;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Serial number of the remote device - Applies to: blaze
Serial number of the remote device. This value only changes when the Device Update List command is executed.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceSerialNumber" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& DeviceSerialNumber;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Returns the transport layer of the device - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceType" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<DeviceTypeEnums>& DeviceType;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Name of the device vendor - Applies to: CoaXPress and blaze
Name of the device vendor. This value only changes when the Device Update List command is executed.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=DeviceVendorName" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& DeviceVendorName;
//@}
//! \name Categories: EventAcquisitionTriggerData
//@{
/*!
\brief AcquisitionTrigger - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventAcquisitionTrigger" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventAcquisitionTrigger;
//@}
//! \name Categories: EventAcquisitionTriggerData
//@{
/*!
\brief AcquisitionTrigger SoftCounter - Applies to: CoaXPress
Software counter for event 'AcquisitionTrigger'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventAcquisitionTriggerSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventAcquisitionTriggerSoftCounter;
//@}
//! \name Categories: EventAcquisitionTriggerData
//@{
/*!
\brief AcquisitionTrigger Timestamp - Applies to: CoaXPress
Timestamp of event 'AcquisitionTrigger'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventAcquisitionTriggerTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventAcquisitionTriggerTimestamp;
//@}
//! \name Categories: EventDeviceLostData
//@{
/*!
\brief Returns the unique identifier of the Device Lost event - Applies to: CoaXPress and blaze
Returns the unique Identifier of the Device Lost event.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventDeviceLost" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventDeviceLost;
//@}
//! \name Categories: EventDeviceLostData
//@{
/*!
\brief DeviceLost SoftCounter - Applies to: CoaXPress
Software counter for event 'DeviceLost'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventDeviceLostSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventDeviceLostSoftCounter;
//@}
//! \name Categories: EventFrameTransferEndData
//@{
/*!
\brief FrameTransferEnd - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTransferEnd" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTransferEnd;
//@}
//! \name Categories: EventFrameTransferEndData
//@{
/*!
\brief FrameTransferEnd SoftCounter - Applies to: CoaXPress
Software counter for event 'FrameTransferEnd'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTransferEndSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTransferEndSoftCounter;
//@}
//! \name Categories: EventFrameTransferEndData
//@{
/*!
\brief FrameTransferEnd Timestamp - Applies to: CoaXPress
Timestamp of event 'FrameTransferEnd'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTransferEndTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTransferEndTimestamp;
//@}
//! \name Categories: EventFrameTransferStartData
//@{
/*!
\brief FrameTransferStart - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTransferStart" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTransferStart;
//@}
//! \name Categories: EventFrameTransferStartData
//@{
/*!
\brief FrameTransferStart SoftCounter - Applies to: CoaXPress
Software counter for event 'FrameTransferStart'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTransferStartSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTransferStartSoftCounter;
//@}
//! \name Categories: EventFrameTransferStartData
//@{
/*!
\brief FrameTransferStart Timestamp - Applies to: CoaXPress
Timestamp of event 'FrameTransferStart'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTransferStartTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTransferStartTimestamp;
//@}
//! \name Categories: EventFrameTriggerMissedData
//@{
/*!
\brief FrameTriggerMissed - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTriggerMissed" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTriggerMissed;
//@}
//! \name Categories: EventFrameTriggerMissedData
//@{
/*!
\brief FrameTriggerMissed SoftCounter - Applies to: CoaXPress
Software counter for event 'FrameTriggerMissed'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTriggerMissedSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTriggerMissedSoftCounter;
//@}
//! \name Categories: EventFrameTriggerMissedData
//@{
/*!
\brief FrameTriggerMissed Timestamp - Applies to: CoaXPress
Timestamp of event 'FrameTriggerMissed'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventFrameTriggerMissedTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventFrameTriggerMissedTimestamp;
//@}
//! \name Categories: EventControl
//@{
/*!
\brief Sets whether the host application is notified of the selected event - Applies to: CoaXPress and blaze
Visibility: Expert
Selected by: EventSelector
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventNotification" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<EventNotificationEnums>& EventNotification;
//@}
//! \name Categories: EventOverflowData
//@{
/*!
\brief Overflow - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventOverflow" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventOverflow;
//@}
//! \name Categories: EventOverflowData
//@{
/*!
\brief Overflow FrameId - Applies to: CoaXPress
Camera FrameID
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventOverflowFrameId" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventOverflowFrameId;
//@}
//! \name Categories: EventOverflowData
//@{
/*!
\brief Overflow Is Complete - Applies to: CoaXPress
Frame Is Complete
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventOverflowIsComplete" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& EventOverflowIsComplete;
//@}
//! \name Categories: EventOverflowData
//@{
/*!
\brief Overflow Is Lost - Applies to: CoaXPress
Frame Is Lost
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventOverflowIsLost" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& EventOverflowIsLost;
//@}
//! \name Categories: EventOverflowData
//@{
/*!
\brief Overflow Is Truncated - Applies to: CoaXPress
Frame Is Truncated
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventOverflowIsTruncated" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& EventOverflowIsTruncated;
//@}
//! \name Categories: EventOverflowData
//@{
/*!
\brief Overflow SoftCounter - Applies to: CoaXPress
Software counter for event 'Overflow'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventOverflowSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventOverflowSoftCounter;
//@}
//! \name Categories: EventOverflowData
//@{
/*!
\brief Overflow Timestamp - Applies to: CoaXPress
Timestamp of event 'Overflow'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventOverflowTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventOverflowTimestamp;
//@}
//! \name Categories: EventControl
//@{
/*!
\brief Sets which event to signal to the host application - Applies to: CoaXPress and blaze
Visibility: Expert
Selecting Parameters: EventNotification
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<EventSelectorEnums>& EventSelector;
//@}
//! \name Categories: EventTriggerExceededPeriodLimitsData
//@{
/*!
\brief TriggerExceededPeriodLimits - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerExceededPeriodLimits" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerExceededPeriodLimits;
//@}
//! \name Categories: EventTriggerExceededPeriodLimitsData
//@{
/*!
\brief TriggerExceededPeriodLimits SoftCounter - Applies to: CoaXPress
Software counter for event 'TriggerExceededPeriodLimits'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerExceededPeriodLimitsSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerExceededPeriodLimitsSoftCounter;
//@}
//! \name Categories: EventTriggerExceededPeriodLimitsData
//@{
/*!
\brief TriggerExceededPeriodLimits Timestamp - Applies to: CoaXPress
Timestamp of event 'TriggerExceededPeriodLimits'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerExceededPeriodLimitsTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerExceededPeriodLimitsTimestamp;
//@}
//! \name Categories: EventTriggerQueueFilllevelThresholdOffData
//@{
/*!
\brief TriggerQueueFilllevelThresholdOff - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerQueueFilllevelThresholdOff" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerQueueFilllevelThresholdOff;
//@}
//! \name Categories: EventTriggerQueueFilllevelThresholdOffData
//@{
/*!
\brief TriggerQueueFilllevelThresholdOff SoftCounter - Applies to: CoaXPress
Software counter for event 'TriggerQueueFilllevelThresholdOff'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerQueueFilllevelThresholdOffSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerQueueFilllevelThresholdOffSoftCounter;
//@}
//! \name Categories: EventTriggerQueueFilllevelThresholdOffData
//@{
/*!
\brief TriggerQueueFilllevelThresholdOff Timestamp - Applies to: CoaXPress
Timestamp of event 'TriggerQueueFilllevelThresholdOff'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerQueueFilllevelThresholdOffTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerQueueFilllevelThresholdOffTimestamp;
//@}
//! \name Categories: EventTriggerQueueFilllevelThresholdOnData
//@{
/*!
\brief TriggerQueueFilllevelThresholdOn - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerQueueFilllevelThresholdOn" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerQueueFilllevelThresholdOn;
//@}
//! \name Categories: EventTriggerQueueFilllevelThresholdOnData
//@{
/*!
\brief TriggerQueueFilllevelThresholdOn SoftCounter - Applies to: CoaXPress
Software counter for event 'TriggerQueueFilllevelThresholdOn'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerQueueFilllevelThresholdOnSoftCounter" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerQueueFilllevelThresholdOnSoftCounter;
//@}
//! \name Categories: EventTriggerQueueFilllevelThresholdOnData
//@{
/*!
\brief TriggerQueueFilllevelThresholdOn Timestamp - Applies to: CoaXPress
Timestamp of event 'TriggerQueueFilllevelThresholdOn'
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=EventTriggerQueueFilllevelThresholdOnTimestamp" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& EventTriggerQueueFilllevelThresholdOnTimestamp;
//@}
//! \name Categories: BufferStatus
//@{
/*!
\brief Current buffer fill level - Applies to: CoaXPress
Current buffer fill level. This value allows you to check whether the average input bandwidth of the camera is too high to be processed by the applet.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=FillLevel" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& FillLevel;
//@}
//! \name Categories: OutputFormat
//@{
/*!
\brief Sets the pixel format of the image that is output to the computer - Applies to: CoaXPress
Sets the pixel format of the image that is output to the computer. The data is converted from the internal bit width and color format to the output format selected. This setting is not related to the pixel format input from the camera sensor. For more information, see the Pixel Format parameter documentation.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Format" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<FormatEnums>& Format;
//@}
//! \name Categories: External
//@{
/*!
\brief Current input signal levels of all front GPI inputs (bit mask) - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=FrontGPI" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& FrontGPI;
//@}
//! \name Categories: External
//@{
/*!
\brief GPI State - Applies to: CoaXPress
Current input signal levels of all GPI inputs (Bitmask).
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=GPI" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& GPI;
//@}
//! \name Categories: Gentl
//@{
/*!
\brief Applies to: CoaXPress
Ignore the FG output format and manage it internally in the GenTL producer
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=GentlInfoIgnorefgformat" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& GentlInfoIgnorefgformat;
//@}
//! \name Categories: Gentl
//@{
/*!
\brief Applies to: CoaXPress
Version of the GenTL description Interface in the applet.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=GentlInfoVersion" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& GentlInfoVersion;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Current gateway IP address of the GVCP interface of the remote device - Applies to: blaze
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=GevDeviceGateway" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& GevDeviceGateway;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Current IP address of the GVCP interface of the remote device - Applies to: blaze
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=GevDeviceIPAddress" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& GevDeviceIPAddress;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief 48-bit MAC address of the GVCP interface of the remote device - Applies to: blaze
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=GevDeviceMACAddress" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& GevDeviceMACAddress;
//@}
//! \name Categories: DeviceInformation
//@{
/*!
\brief Current subnet mask of the GVCP interface of the remote device - Applies to: blaze
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=GevDeviceSubnetMask" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& GevDeviceSubnetMask;
//@}
//! \name Categories: Root
//@{
/*!
\brief Heartbeat timeout value on the host side in milliseconds - Applies to: GigE
Heartbeat timeout value on the host side in milliseconds. This parameter is linked with the Heartbeat Timeout camera parameter. If the camera parameter changes, the host parameter changes accordingly, and vice versa.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=HeartbeatTimeout" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& HeartbeatTimeout;
//@}
//! \name Categories: ROI
//@{
/*!
\brief Height of the image ROI on the host side - Applies to: CoaXPress
Height of the image ROI on the host side. This parameter is linked with the Height camera parameter. If the camera parameter changes, the host parameter changes accordingly, but not vice versa. The host parameter should not be set to a value different from the camera parameter.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Height" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Height;
//@}
//! \name Categories: ImageSelector
//@{
/*!
\brief Defines which image in a sequence is grabbed - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ImageSelect" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& ImageSelect;
//@}
//! \name Categories: ImageSelector
//@{
/*!
\brief Select the length of an image sequence - Applies to: CoaXPress
Select the length of an image sequence. Only a single image of the sequence is grabbed.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ImageSelectPeriod" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& ImageSelectPeriod;
//@}
//! \name Categories: DeviceControl
//@{
/*!
\brief Specifies maximum number of tries before failing the control channel commands - Applies to: blaze
Visibility: Guru
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LinkCommandRetryCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LinkCommandRetryCount;
//@}
//! \name Categories: DeviceControl
//@{
/*!
\brief Specifies application timeout for the control channel communication - Applies to: blaze
Specifies application timeout for the control channel communication. Up to DeviceLinkCommandRetryCount attempts with this timeout are made before a command fails with a timeout error.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LinkCommandTimeout" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& LinkCommandTimeout;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Filename with custom lookup table values - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutCustomFile" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& LutCustomFile;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Switch the LUT and processing functionality on or off - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutEnable" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<LutEnableEnums>& LutEnable;
//@}
//! \name Categories: AppletProperties
//@{
/*!
\brief Type of lookup table implementation - Applies to: CoaXPress
Type of LUT implementation.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutImplementationType" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<LutImplementationTypeEnums>& LutImplementationType;
//@}
//! \name Categories: AppletProperties
//@{
/*!
\brief Pixel bit depth at the lookup table input - Applies to: CoaXPress
Pixel bit depth at LUT input.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutInputPixelBitDepth" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutInputPixelBitDepth;
//@}
//! \name Categories: AppletProperties
//@{
/*!
\brief Pixel bit depth at the lookup table output - Applies to: CoaXPress
Pixel bit depth at LUT output.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutOutputPixelBitDepth" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutOutputPixelBitDepth;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Save current lookup table configuration - Applies to: CoaXPress
Save current LUT configuration.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutSaveFile" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& LutSaveFile;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Set the type of the lookup table: Custom values or applet processor - Applies to: CoaXPress
Enables the LUT to be loaded with custom values or uses the applet's processor.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutType" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<LutTypeEnums>& LutType;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Field with lookup table values - Applies to: CoaXPress
Field with LUT Values.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValue" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValue;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Field with blue lookup table values - Applies to: CoaXPress
Field with blue LUT Values.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValueBlue" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValueBlue;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValueBlueSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValueBlueSelector;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Field with green looup table values - Applies to: CoaXPress
Field with green LUT Values.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValueGreen" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValueGreen;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValueGreenSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValueGreenSelector;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Field with red lookup table values - Applies to: CoaXPress
Field with red LUT Values.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValueRed" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValueRed;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValueRedSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValueRedSelector;
//@}
//! \name Categories: LookupTable
//@{
/*!
\brief Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=LutValueSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& LutValueSelector;
//@}
//! \name Categories: Root
//@{
/*!
\brief Maximum number of retries for read operations after a read operation has timed out - Applies to: GigE
Visibility: Guru
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=MaxRetryCountRead" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& MaxRetryCountRead;
//@}
//! \name Categories: Root
//@{
/*!
\brief Maximum number of retries for write operations after a write operation has timed out - Applies to: GigE
Visibility: Guru
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=MaxRetryCountWrite" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& MaxRetryCountWrite;
//@}
//! \name Categories: Root
//@{
/*!
\brief Enables mapping of certain SFNC 1 x node names to SFNC 2 x node names - Applies to: GigE and USB
Enables mapping of certain SFNC 1.x node names to SFNC 2.x node names. This allows you to write code for camera devices that are compatible with different SFNC (Standard Features Naming Convention) versions. Available for USB camera devices only.
Visibility: Guru
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=MigrationModeEnable" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& MigrationModeEnable;
//@}
//! \name Categories: OutStatistics
//@{
/*!
\brief Returns whether missing frames are reported - Applies to: CoaXPress
Returns whether missing frames are reported. If no frame is received for a trigger pulse, the parameter is set to Yes.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=MissingCameraFrameResponse" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<MissingCameraFrameResponseEnums>& MissingCameraFrameResponse;
//@}
//! \name Categories: OutStatistics
//@{
/*!
\brief Clears the Missing Camera Frame Response parameter - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=MissingCameraFrameResponseClear" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::ICommandEx& MissingCameraFrameResponseClear;
//@}
//! \name Categories: ROI
//@{
/*!
\brief Acquisition ROI x-offset, independent of camera ROI - Applies to: CoaXPress
X-offset of the acquisition ROI independent of the camera ROI.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=OffsetX" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& OffsetX;
//@}
//! \name Categories: ROI
//@{
/*!
\brief Acquisition ROI y-offset, independent of camera ROI - Applies to: CoaXPress
Y-offset of the acquisition ROI independent of the camera ROI.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=OffsetY" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& OffsetY;
//@}
//! \name Categories: ImageFormatControl
//@{
/*!
\brief Automatically outputs packed formats instead of unpacked ones - Applies to: CoaXPress
Automatically outputs packed formats instead of unpacked ones. This parameter is only available if the Automatic Format Control parameter is enabled.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=OutputPackedFormats" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IBooleanEx& OutputPackedFormats;
//@}
//! \name Categories: BufferStatus
//@{
/*!
\brief Indicates whether the image buffer is currently in overflow state - Applies to: CoaXPress
Indicates whether if the image buffer is currently in overflow state. An overflow results in the loss of images. The parameter is reset at each readout cycle.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Overflow" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Overflow;
//@}
//! \name Categories: BufferStatus
//@{
/*!
\brief Select the content of the overflow event - Applies to: CoaXPress
An overflow event can be generated on each incomplete, lost or correct frame. It is possible to select all permutations of these three events to be reported via overflow event.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=OverflowEventSelect" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<OverflowEventSelectEnums>& OverflowEventSelect;
//@}
//! \name Categories: BufferStatus
//@{
/*!
\brief Overflow handling will be inactive once the buffer filllevel is below this Value - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=OverflowOffThreshold" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& OverflowOffThreshold;
//@}
//! \name Categories: BufferStatus
//@{
/*!
\brief Overflow handling will be active once the buffer filllevel is above this Value Frames will be interrupted - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=OverflowOnThreshold" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& OverflowOnThreshold;
//@}
//! \name Categories: BufferStatus
//@{
/*!
\brief Overflow handling will be active once the buffer filllevel is above this Value, after the currently active frame is completed - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=OverflowSyncOnThreshold" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& OverflowSyncOnThreshold;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Number of packet errors - Applies to: CoaXPress
Number of packet errors. This parameter indicates that CXP stream packets are lost.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=PacketTagErrorCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& PacketTagErrorCount;
//@}
//! \name Categories: OutputFormat
//@{
/*!
\brief Applet-internal processing bit depth - Applies to: CoaXPress
Applet-internal processing bit depth. This is the maximum bit depth at which pixels are processed. If you select a highter output and input bit depth, data may be truncated.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=PixelDepth" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& PixelDepth;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Sets the format of the pixel data transmitted by the camera - Applies to: CoaXPress
Sets the format of the pixel data transmitted by the camera. This setting has to match the pixel format set in the camera.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=PixelFormat" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<PixelFormatEnums>& PixelFormat;
//@}
//! \name Categories: Processing
//@{
/*!
\brief Gain correction value - Applies to: CoaXPress
Gain correction value. Available when LUT functionality is enabled.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ProcessingGain" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& ProcessingGain;
//@}
//! \name Categories: Processing
//@{
/*!
\brief Gamma correction value - Applies to: CoaXPress
Gamma correction value. Available when LUT functionality is enabled.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ProcessingGamma" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& ProcessingGamma;
//@}
//! \name Categories: Processing
//@{
/*!
\brief Invert output - Applies to: CoaXPress
Invert output. Available when LUT functionality is enabled.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ProcessingInvert" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<ProcessingInvertEnums>& ProcessingInvert;
//@}
//! \name Categories: Processing
//@{
/*!
\brief Offset correction value - Applies to: CoaXPress
Offset correction value. Available when LUT functionality is enabled.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ProcessingOffset" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& ProcessingOffset;
//@}
//! \name Categories: Root
//@{
/*!
\brief Read access timeout value in milliseconds - Applies to: GigE
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ReadTimeout" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& ReadTimeout;
//@}
//! \name Categories: WhiteBalance
//@{
/*!
\brief Blue gain of the white balancing - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ScalingFactorBlue" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& ScalingFactorBlue;
//@}
//! \name Categories: WhiteBalance
//@{
/*!
\brief Green gain of the white balancing - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ScalingFactorGreen" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& ScalingFactorGreen;
//@}
//! \name Categories: WhiteBalance
//@{
/*!
\brief Red gain of the white balancing - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=ScalingFactorRed" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& ScalingFactorRed;
//@}
//! \name Categories: SoftwareTrigger
//@{
/*!
\brief Sends a software trigger pulse - Applies to: CoaXPress
Sends a software trigger pulse or adds pulses to the trigger queue if it is enabled.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SendSoftwareTrigger" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::ICommandEx& SendSoftwareTrigger;
//@}
//! \name Categories: SensorGeometry
//@{
/*!
\brief Height of the sensor - Applies to: CoaXPress
Sensor Height in selected tap geometry. Value is ignored if vantage point = TopLeft. Available DRAM and SensorWidth limit the maximum SensorHeight.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SensorHeight" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SensorHeight;
//@}
//! \name Categories: SensorGeometry
//@{
/*!
\brief Width of the sensor - Applies to: CoaXPress
Sensor width in selected tap geometry. Value is ignored if vantage point = Top-Left. Available DRAM and SensorHeight limit the maximum SensorWidth.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SensorWidth" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SensorWidth;
//@}
//! \name Categories: SoftwareTrigger
//@{
/*!
\brief Indicates whether the software trigger is busy - Applies to: CoaXPress
Indicates whether the software trigger is busy. This allows you to find out whether the trigger system is still processing software trigger pulses.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SoftwareTriggerIsBusy" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<SoftwareTriggerIsBusyEnums>& SoftwareTriggerIsBusy;
//@}
//! \name Categories: SoftwareTrigger
//@{
/*!
\brief Number of pulses in queue to be processed - Applies to: CoaXPress
Number of pulses in queue to be processed. The Queue parameter needs to be enabled for this.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SoftwareTriggerQueueFillLevel" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SoftwareTriggerQueueFillLevel;
//@}
//! \name Categories: ExtendedDeviceControl and Root
//@{
/*!
\brief Number of timeouts during read and write operations when waiting for a response from the device - Applies to: GigE and blaze
Visibility: Guru
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=StatisticReadWriteTimeoutCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& StatisticReadWriteTimeoutCount;
//@}
//! \name Categories: Statistic
//@{
/*!
\brief Last error status of a read or write operation - Applies to: USB
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Statistic_Last_Error_Status" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Statistic_Last_Error_Status;
//@}
//! \name Categories: Statistic
//@{
/*!
\brief Last error status of a read or write operation - Applies to: USB
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Statistic_Last_Error_Status_Text" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& Statistic_Last_Error_Status_Text;
//@}
//! \name Categories: Statistic
//@{
/*!
\brief Number of failed read operations - Applies to: USB
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Statistic_Read_Operations_Failed_Count" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Statistic_Read_Operations_Failed_Count;
//@}
//! \name Categories: Statistic
//@{
/*!
\brief Number of read pipe resets - Applies to: USB
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Statistic_Read_Pipe_Reset_Count" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Statistic_Read_Pipe_Reset_Count;
//@}
//! \name Categories: Statistic
//@{
/*!
\brief Number of failed write operations - Applies to: USB
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Statistic_Write_Operations_Failed_Count" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Statistic_Write_Operations_Failed_Count;
//@}
//! \name Categories: Statistic
//@{
/*!
\brief Number of write pipe resets - Applies to: USB
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Statistic_Write_Pipe_Reset_Count" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Statistic_Write_Pipe_Reset_Count;
//@}
//! \name Categories: StreamEnumeration
//@{
/*!
\brief User-friendly name of the selected stream - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=StreamDisplayName" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& StreamDisplayName;
//@}
//! \name Categories: StreamEnumeration
//@{
/*!
\brief Device-wide unique ID of the data stream - Applies to: CoaXPress and blaze
Visibility: Beginner
Selected by: StreamSelector
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=StreamID" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IStringEx& StreamID;
//@}
//! \name Categories: StreamEnumeration
//@{
/*!
\brief Sets the stream channel - Applies to: CoaXPress and blaze
Sets the stream channel. The parameter is 0-based in order to match the index of the C interface.
Visibility: Beginner
Selecting Parameters: StreamID
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=StreamSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& StreamSelector;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Byte Alignment 8b10b locked
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorByteAlignment8b10bLocked" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<SystemmonitorByteAlignment8b10bLockedEnums>& SystemmonitorByteAlignment8b10bLocked;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the Channel Current.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorChannelCurrent" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorChannelCurrent;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorChannelCurrentSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorChannelCurrentSelector;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the Channel Voltage.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorChannelVoltage" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorChannelVoltage;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorChannelVoltageSelector" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorChannelVoltageSelector;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the current PCIe link speed in Gibibyte (2^30 byte).
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorCurrentLinkSpeed" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorCurrentLinkSpeed;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Camera scan mode - Applies to: CoaXPress
This parameter informs on the current transfer mode, used by the camera. The transfer can be an areascan (= 0) or linescan (= 1) image.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorCxpImageLineMode" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorCxpImageLineMode;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Disparity 8b 10b errors
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorDisparity8b10bError" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorDisparity8b10bError;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Shows the external power state of the board.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorExternalPower" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<SystemmonitorExternalPowerEnums>& SystemmonitorExternalPower;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the current FPGA die temperature.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorFpgaTemperature" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorFpgaTemperature;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the current FPGA auxiliary Vcc.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorFpgaVccAux" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorFpgaVccAux;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the current FPGA BRAM Vcc.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorFpgaVccBram" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorFpgaVccBram;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the current FPGA internal Vcc.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorFpgaVccInt" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorFpgaVccInt;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Not in table 8b 10b errors
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorNotInTable8b10bError" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorNotInTable8b10bError;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Number of packet buffer overflows - Applies to: CoaXPress
Represents the number of overflows, if an overflow occurred due to not correctly aligned package order.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorPacketbufferOverflowCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorPacketbufferOverflowCount;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Source of packet buffer overflows - Applies to: CoaXPress
Represents the port, which has overflows due to not correctly aligned package order.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorPacketbufferOverflowSource" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorPacketbufferOverflowSource;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the PCIe trained payload size.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorPcieTrainedPayloadSize" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorPcieTrainedPayloadSize;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the PCIe trained request size.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorPcieTrainedRequestSize" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorPcieTrainedRequestSize;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Returns the port bit rate
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorPortBitRate" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& SystemmonitorPortBitRate;
//@}
//! \name Categories: Miscellaneous
//@{
/*!
\brief Applies to: CoaXPress
Shows the current power over CXP state.
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorPowerOverCxpState" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<SystemmonitorPowerOverCxpStateEnums>& SystemmonitorPowerOverCxpState;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Number of used connections - Applies to: CoaXPress
The currently used number of CXP ports used in this process.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=SystemmonitorUsedCxpConnections" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& SystemmonitorUsedCxpConnections;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Number of trigger acknowledgement packets sent by the camera have been received by the frame grabber - Applies to: CoaXPress
Number of trigger acknowledgement packets sent by the camera (in response to trigger edge packets sent before) have been received by the frame grabber.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerAcknowledgementCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerAcknowledgementCount;
//@}
//! \name Categories: CameraOutSignalMapping
//@{
/*!
\brief Sets the output source to be connected to a camera signal channel - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerCameraOutSelect" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerCameraOutSelectEnums>& TriggerCameraOutSelect;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Number of trigger events sent to the camera - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerEventCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerEventCount;
//@}
//! \name Categories: OutStatistics
//@{
/*!
\brief Returns whether the input signal frequency exceeded the maximum specified - Applies to: CoaXPress
Returns whether the input signal frequency exceeded the maximum specified. If the parameter returns Yes, signals were dropped.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerExceededPeriodLimits" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerExceededPeriodLimitsEnums>& TriggerExceededPeriodLimits;
//@}
//! \name Categories: OutStatistics
//@{
/*!
\brief Clears the Trigger Exceeded Period Limits parameter - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerExceededPeriodLimitsClear" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::ICommandEx& TriggerExceededPeriodLimitsClear;
//@}
//! \name Categories: External
//@{
/*!
\brief Input debounce time for trigger input signals (in microseconds) - Applies to: CoaXPress
Input debounce time for trigger input signals (in microseconds). This parameter allows you to filter out invalid signals by specifying a minimum signal length.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInDebounce" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerInDebounce;
//@}
//! \name Categories: External
//@{
/*!
\brief Factor by which the trigger input signal is downscaled - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInDownscale" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerInDownscale;
//@}
//! \name Categories: External
//@{
/*!
\brief Phase for selecting the desired pulse in the sequence - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInDownscalePhase" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerInDownscalePhase;
//@}
//! \name Categories: External
//@{
/*!
\brief Sets the polarity of the trigger input signal - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInPolarity" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerInPolarityEnums>& TriggerInPolarity;
//@}
//! \name Categories: External
//@{
/*!
\brief Sets the trigger input source - Applies to: CoaXPress
Sets the trigger input source for external trigger mode.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInSource" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerInSourceEnums>& TriggerInSource;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Current frequency of the input pulses - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsFrequency" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerInStatisticsFrequency;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Maximum input frequency detected - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsMaximumFrequency" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerInStatisticsMaximumFrequency;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Clears the minimum and maximum frequency values - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsMinMaxFrequencyClear" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::ICommandEx& TriggerInStatisticsMinMaxFrequencyClear;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Minimum input frequency detected - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsMinimumFrequency" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerInStatisticsMinimumFrequency;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Sets the polarity of the trigger input signal for statistics - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsPolarity" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerInStatisticsPolarityEnums>& TriggerInStatisticsPolarity;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Number of input pulses - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsPulseCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerInStatisticsPulseCount;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Clears the input signal pulse counter - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsPulseCountClear" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::ICommandEx& TriggerInStatisticsPulseCountClear;
//@}
//! \name Categories: InStatistics
//@{
/*!
\brief Sets the input source for statistics - Applies to: CoaXPress
Sets the trigger input source for statistics.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerInStatisticsSource" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerInStatisticsSourceEnums>& TriggerInStatisticsSource;
//@}
//! \name Categories: Sequencer
//@{
/*!
\brief Upscales, i e , duplicates, the number of trigger pulses generated externally or via software with the period specified by the Trigger Output Frequency parameter - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerMultiplyPulses" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerMultiplyPulses;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of Front GPO 0 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectFrontGPO0" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectFrontGPO0Enums>& TriggerOutSelectFrontGPO0;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of Front GPO 1 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectFrontGPO1" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectFrontGPO1Enums>& TriggerOutSelectFrontGPO1;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 0 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO0" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO0Enums>& TriggerOutSelectGPO0;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 1 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO1" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO1Enums>& TriggerOutSelectGPO1;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 2 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO2" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO2Enums>& TriggerOutSelectGPO2;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 3 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO3" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO3Enums>& TriggerOutSelectGPO3;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 4 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO4" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO4Enums>& TriggerOutSelectGPO4;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 5 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO5" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO5Enums>& TriggerOutSelectGPO5;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 6 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO6" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO6Enums>& TriggerOutSelectGPO6;
//@}
//! \name Categories: DigitalOutput
//@{
/*!
\brief Sets the output source of GPO 7 - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutSelectGPO7" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutSelectGPO7Enums>& TriggerOutSelectGPO7;
//@}
//! \name Categories: OutStatistics
//@{
/*!
\brief Number of output pulses - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutStatisticsPulseCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerOutStatisticsPulseCount;
//@}
//! \name Categories: OutStatistics
//@{
/*!
\brief Clears the output signal pulse counter - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutStatisticsPulseCountClear" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::ICommandEx& TriggerOutStatisticsPulseCountClear;
//@}
//! \name Categories: OutStatistics
//@{
/*!
\brief Sets the output source for statistics - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutStatisticsSource" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutStatisticsSourceEnums>& TriggerOutStatisticsSource;
//@}
//! \name Categories: OutputEvents
//@{
/*!
\brief Select the pulse form generator for event monitoring - Applies to: CoaXPress
Select the pulse form generator for event monitoring.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutputEventSelect" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerOutputEventSelectEnums>& TriggerOutputEventSelect;
//@}
//! \name Categories: Trigger
//@{
/*!
\brief Maximum trigger output frequency - Applies to: CoaXPress
Maximum trigger output frequency. If the internal generator is used, it will use the frequency specified there. If an external source is used, this value determines the maximum allowed value. External trigger signals exceeding this value will be discarded. For more information, see the applet documentation.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerOutputFrequency" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerOutputFrequency;
//@}
//! \name Categories: PulseFormGenerator0
//@{
/*!
\brief Delay between the input and the output of the pulse form generator - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator0Delay" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator0Delay;
//@}
//! \name Categories: PulseFormGenerator0
//@{
/*!
\brief Downscale factor at the pulse form generator input - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator0Downscale" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator0Downscale;
//@}
//! \name Categories: PulseFormGenerator0
//@{
/*!
\brief Phase for selecting the desired pulse in the sequence - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator0DownscalePhase" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator0DownscalePhase;
//@}
//! \name Categories: PulseFormGenerator0
//@{
/*!
\brief Width of the output signal - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator0Width" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator0Width;
//@}
//! \name Categories: PulseFormGenerator1
//@{
/*!
\brief Delay between the input and the output of the pulse form generator - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator1Delay" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator1Delay;
//@}
//! \name Categories: PulseFormGenerator1
//@{
/*!
\brief Downscale factor at the pulse form generator input - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator1Downscale" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator1Downscale;
//@}
//! \name Categories: PulseFormGenerator1
//@{
/*!
\brief Phase for selecting the desired pulse in the sequence - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator1DownscalePhase" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator1DownscalePhase;
//@}
//! \name Categories: PulseFormGenerator1
//@{
/*!
\brief Width of the output signal - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator1Width" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator1Width;
//@}
//! \name Categories: PulseFormGenerator2
//@{
/*!
\brief Delay between the input and the output of the pulse form generator - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator2Delay" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator2Delay;
//@}
//! \name Categories: PulseFormGenerator2
//@{
/*!
\brief Downscale factor at the pulse form generator input - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator2Downscale" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator2Downscale;
//@}
//! \name Categories: PulseFormGenerator2
//@{
/*!
\brief Phase for selecting the desired pulse in the sequence - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator2DownscalePhase" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator2DownscalePhase;
//@}
//! \name Categories: PulseFormGenerator2
//@{
/*!
\brief Width of the output signal - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator2Width" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator2Width;
//@}
//! \name Categories: PulseFormGenerator3
//@{
/*!
\brief Delay between the input and the output of the pulse form generator - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator3Delay" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator3Delay;
//@}
//! \name Categories: PulseFormGenerator3
//@{
/*!
\brief Downscale factor at the pulse form generator input - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator3Downscale" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator3Downscale;
//@}
//! \name Categories: PulseFormGenerator3
//@{
/*!
\brief Phase for selecting the desired pulse in the sequence - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator3DownscalePhase" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerPulseFormGenerator3DownscalePhase;
//@}
//! \name Categories: PulseFormGenerator3
//@{
/*!
\brief Width of the output signal - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerPulseFormGenerator3Width" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IFloatEx& TriggerPulseFormGenerator3Width;
//@}
//! \name Categories: Queue
//@{
/*!
\brief Fill level of the trigger queue - Applies to: CoaXPress
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerQueueFillLevel" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerQueueFillLevel;
//@}
//! \name Categories: Queue
//@{
/*!
\brief Set the threshold for generating a queue fill level OFF event - Applies to: CoaXPress
Set the threshold for generating a queue fill level OFF event.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerQueueFillLevelEventOffThreshold" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerQueueFillLevelEventOffThreshold;
//@}
//! \name Categories: Queue
//@{
/*!
\brief Set the threshold for generating a queue fill level ON event - Applies to: CoaXPress
Set the threshold for generating a queue fill level ON event.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerQueueFillLevelEventOnThreshold" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerQueueFillLevelEventOnThreshold;
//@}
//! \name Categories: Queue
//@{
/*!
\brief Enables/disable the trigger queue mode - Applies to: CoaXPress
Enables/disable the trigger queue mode. The maximum output frequency is specified by the Trigger Output Frequency parameter.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerQueueMode" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerQueueModeEnums>& TriggerQueueMode;
//@}
//! \name Categories: Trigger
//@{
/*!
\brief Sets the state of the trigger system - Applies to: CoaXPress
Sets the state of the trigger system. The state of the trigger system is related to the trigger mode. This parameter enables or disables the trigger processing.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerState" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<TriggerStateEnums>& TriggerState;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Indicates a trigger frequency violation - Applies to: CoaXPress
Indicates a distance of two trigger edges violating the minimum edge frequency.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=TriggerWaveViolation" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& TriggerWaveViolation;
//@}
//! \name Categories: CoaXPress
//@{
/*!
\brief Number of uncorrected errors - Applies to: CoaXPress
Number of uncorrected errors. Bit[2] indicates multiple byte errors in CXP stream packets.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=UncorrectedErrorCount" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& UncorrectedErrorCount;
//@}
//! \name Categories: SensorGeometry
//@{
/*!
\brief Choose vantage point for horizontal and/or vertical mirroring - Applies to: CoaXPress
Vantage point. Use for mirroring. If VantagePoint is set to TopRight or BottomRight Width + XOffset must be smaller than SensorWidth. If VantagePoint is set to BottomLeft or BottomRight the Height + YOffset must be smaller than SensorHeight.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=VantagePoint" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IEnumParameterT<VantagePointEnums>& VantagePoint;
//@}
//! \name Categories: ROI
//@{
/*!
\brief Width of the image ROI on the host side - Applies to: CoaXPress
Width of the image ROI on the host side. This parameter is linked with the Width camera parameter. If the camera parameter changes, the host parameter changes accordingly, but not vice versa. The host parameter should not be set to a value different from the camera parameter.
Visibility: Expert
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=Width" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& Width;
//@}
//! \name Categories: Root
//@{
/*!
\brief Write access timeout in milliseconds - Applies to: GigE
Visibility: Beginner
The <a href="https://docs.baslerweb.com/?rhcsh=1&rhmapid=WriteTimeout" target="_blank">feature documentation</a> may provide more information.
*/
Pylon::IIntegerEx& WriteTimeout;
//@}
private:
//! \cond HIDE_CLASS_METHODS
//! not implemented copy constructor
CUniversalTLParams_Params_v7_3_0(CUniversalTLParams_Params_v7_3_0&);
//! not implemented assignment operator
CUniversalTLParams_Params_v7_3_0& operator=(CUniversalTLParams_Params_v7_3_0&);
//! \endcond
};
/*!
\brief A parameter class containing all parameters as members that are available for pylon device transport layers
The parameter class is used by the \c Pylon::CBaslerUniversalInstantCamera class.
The \ref sample_ParametrizeCamera_NativeParameterAccess code sample shows how to access camera parameters via the \c Pylon::CBaslerUniversalInstantCamera class.
*/
class CUniversalTLParams_Params : public CUniversalTLParams_Params_v7_3_0
{
//----------------------------------------------------------------------------------------------------------------
// Implementation
//----------------------------------------------------------------------------------------------------------------
protected:
// If you want to show the following methods in the help file
// add the string HIDE_CLASS_METHODS to the ENABLED_SECTIONS tag in the doxygen file
//! \cond HIDE_CLASS_METHODS
//! Constructor
CUniversalTLParams_Params( void )
{
}
//! Destructor
~CUniversalTLParams_Params( void )
{
}
//! Initializes the references
void _Initialize( GENAPI_NAMESPACE::INodeMap* pNodeMap )
{
CUniversalTLParams_Params_v7_3_0::_Initialize( pNodeMap );
}
//! \endcond
};
} // namespace Basler_UniversalTLParams
#endif // BASLER_PYLON_UNIVERSALTLPARAMS_H